ALMIG ADSORPTION DRYERS
Adsorption dryers are used for all applications where a pressure dewpoint of +3°C is not sufficient.
ALMiG Adsorption Dryers offer:
- Cold-regenerating adsorption dryers
- Hot-regenerating adsorption dryers
Cold-regenerating Adsorption Dryers
OekoDry 2000 series
Complete conditioning system with cold-regenerating adsorption dryer, pre- and after-filter and condensate drain.
|
Key data:
- Pressure dew-point:
up to 40°C at 100% nominal load
up to 70°C at 70% nominal load and
a max. inlet temperature of +35°C
- Volumetric flow rates of 5-100 m3/h
- Regenerant air requirements approx. 17% of the nominal volumetric flow rate
- Operating overpressure 4-16 bars
|
|
OekoDry C series
Complete conditioning systems with cold-regenerating adsorption dryers, pre- and after-filter and electronic condensate drain.
|
Key data:
- Pressure dew-points
<20°C
<40°C
<70°C
- Volumetric flow rates of
51000 m3/h
- Regnerant air amount at
PDP:
20°C: 14%
40°C: 15%
70°C: 20%
of the relevant nominal volumetric flow rate
- Operating overpressure 4-16
bars
|
|
OekoDry C series
Complete conditioning system with cold-regenerating adsorption dryer, pre- and after-filter and electronic condensate drain.
|
Key data:
- Pressure dew-points
<20°C
<40°C
<70°C
- Volumetric flow rates of
13508750 m3/h
- Regenerant air amounts at
PDP:
20°C: 14%
40°C: 15%
70°C: 20%
of the relevant nominal volumetric flow rate
- Operating overpressure 4-10
bars
|
|
Hot-regenerating Adsorption Dryers
OekoDry W series
External hot-regenerating adsorption dryers with fan and compressed air loss-free cooling system.
|
Key data:
- Pressure dew-point 40°C at 100% nominal load
- Volumetric flow rates of 3758750 m³/h
- Operating overpressure 410 bars
|
|
Particularly at high outputs and pressure dew-points hot-regenerating adsorption dryers are more efficien and, above all, cheaper in terms of operating costs.
Owing to the suction gas cooling, the OekoDry W series works without compressed air loss. With this system ambient air is fed through the adsorption tank to cool the plant. This lowers the pressure and consequently also the temperature. This makes the OekoDry W series even more efficient and economical. Pressure dew-point 40°C at 100% nominal load.
Cheviot Compressor Services can offer full installation, servicing and maintenance.
|